Product Type Twisted pair cable

General Specifications

Product Number CS30CM
ANSI/TIA Category 6
Cable Component Type Horizontal
Cable Type U/UTP (unshielded)
Conductor Type, singles Solid
Conductors, quantity 8
Jacket Color Blue
Pairs, quantity 4
Transmission Standards ANSI/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class E

Dimensions

Cable Length 304.8 m | 1000 ft
Diameter Over Insulated Conductor 0.909 mm | 0.0358 in
Diameter Over Jacket, nominal 5.410 mm | 0.213 in
Conductor Gauge, singles 24 AWG

Electrical Specifications

Characteristic Impedance 100 ohm
dc Resistance Unbalance, maximum 5 %
dc Resistance, maximum 9.38 ohms/100 m | 2.859 ohms/100 ft
Delay Skew, maximum 45 ns
Dielectric Strength, minimum 1500 Vac | 2500 Vdc
Mutual Capacitance at Frequency 5.6 nF/100 m @ 1 kHz
Nominal Velocity of Propagation (NVP) 68 %
Operating Frequency, maximum 250 MHz
Operating Voltage, maximum 80 V
Propagation Delay, maximum 536 ns/100m @250MHz
Remote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A

Electrical Cable Performance

CS
CommScope
Std
Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
Typ
Typical
IL
Insertion Loss (dB/100m)
NEXT
Near End Crosstalk (dB/100m)
ACR
Attenuation to Crosstalk Ratio (dB/100m))
PSNEXT
Power Sum Near End Crosstalk (db/100m)
PSACR
Power Sum Attenuation to Crosstalk Ratio (dB/100m)
ACRF
Attenuation to Crosstalk Ratio - Far End (dB/100m)
PSACRF
Insertion Loss (dB/100m)
RL
Return Loss (dB)
Frequency IL, STD NEXT, STD ACR, STD PSNEXT, STD PSACR, STD ACRF, STD PSACRF, STD RL, STD TCL, STD ELTCTL, STD
1.00 MHz 2.0 74.3 72.3 72.3 70.3 67.8 64.8 20.0 40.0 35.0
4.00 MHz 3.8 65.3 61.5 63.3 59.5 55.8 52.8 23.0 40.0 23.0
8.00 MHz 5.3 60.8 55.4 58.8 53.4 49.9 46.9 24.5 40.0 16.9
10.00 MHz 6.0 59.3 53.3 57.3 51.3 47.8 44.8 25.0 40.0 15.0
16.00 MHz 7.6 56.2 48.7 54.2 46.7 43.7 40.7 25.0 38.0 10.9
20.00 MHz 8.5 54.8 46.3 52.8 44.3 41.8 38.8 25.0 37.0 9.0
25.00 MHz 9.5 53.3 43.8 51.3 41.8 39.8 36.8 24.3 36.0 7.0
31.25 MHz 10.7 51.9 41.2 49.9 39.2 37.9 34.9 23.6 35.1
62.50 MHz 15.4 47.4 32.0 45.4 30.0 31.9 28.9 21.5 32.0
100.00 MHz 19.8 44.3 24.5 42.3 22.5 27.8 24.8 20.1 30.0
155.00 MHz 25.2 41.4 16.3 39.4 14.3 24.0 21.0 18.8 28.1
200.00 MHz 29.0 39.8 10.8 37.8 8.8 21.8 18.8 18.0 27.0
250.00 MHz 32.8 38.3 5.5 36.3 3.5 19.8 16.8 17.3 26.0

Material Specifications

Conductor Material Bare copper
Insulation Material Polyolefin
Jacket Material PVC

Mechanical Specifications

Minimum Bend Radius Note 4 times the outer cable diameter

Environmental Specifications

Installation temperature 0 °C to +60 °C (-32 °F to +140 °F)
Operating Temperature -20 °C to +60 °C (-4 °F to +140 °F)
Storage Temperature -20 °C to +80 °C (-4 °F to +176 °F)
Environmental Space Non-plenum
Flame Test Method CM | UL 1685

Packaging and Weights

Packaging Type Reel in box